§ 17.23.200. Area and dimensional requirements.  


Latest version.
  • A.

    The following area and dimensional requirements apply to all CA zones:

    Table 17.23.200-1: Area and Dimensional Requirements
    Measurement Type Limit
    Minimum lot area n/a
    Minimum lot width/frontage 50 feet
    Maximum building height 35 feet
    Maximum lot coverage 60%
    Maximum site coverage 80%
    Minimum front setback n/a
    Garage entrance setback n/a
    Minimum rear setback 15 feet from any alley or
    adjacent residential zone
    Minimum side setback 15 feet from any alley or
    adjacent residential zone
    Minimum side setback (street) n/a
    Minimum side setback (alley) 15 feet
    Detached Accessory Structure Requirements
    Minimum rear setback for accessory structures in the rear one-third of the lot 15 feet from any alley or
    adjacent residential zone
    Minimum side setback for accessory structures in the rear one-third of the lot
    Maximum building height Not to exceed the primary
    structure building height
    Maximum building footprint Not to exceed the primary
    structure building footprint

     

    All newly created lots shall have a minimum area adequate to provide for required setbacks and parking.

    A 25% height bonus is available if the detached structure is within the building envelope required of a principal structure in the zone that the property is located.

(Ord. 3577 § 1, 3/21/2017; Ord. 3548 § 14, 1/5/2016; Ord. 3332 § 5, 4/25/2008; Ord. 3272, 2/16/2007; Ord. 3180 § 1 (part), 12/17/2004; Ord. 2977 § 1 (part) 12/26/1997; Ord. 2861 § 1 (part), 3/17/1995; Ord. 2591 § 2, 5/25/1990; Ord. 2293 § 1 (part), 4/4/1984)